Redundancy and failover for telephony
Telephony redundancy and failover mean that backup routes keep calls working when something fails. What does your telephony depend on, what backup routes do you have and how do you know they work? A guide for organisations that cannot afford outages.
In short
- Start with the dependencies: power, network, operators, SBCs, servers, licences, cloud services, DNS and certificates.
- Two operators only help if they are genuinely separate, in network, staff and subcontractors.
- The backup solution needs to handle what matters most, not full capacity.
- A backup route that has never been tested is not a backup route. Test in planned windows and after major changes.
- Check the route for 112 at every test, together with the operator and SOS Alarm, which answers 112 calls in Sweden, and document everything so the plan can be followed on a bad day.
Map the dependencies
Telephony depends on more than the PBX. Go through each dependency and ask what happens if it disappears.
| Dependency | What to ask |
|---|---|
| Power | Uninterruptible power supply (UPS) and backup power for servers, the network, the switches that power the phones, SBCs, DECT base stations and the operator’s equipment on your premises. How long does it last, and are the batteries maintained? |
| Network | Redundant switches and firewalls? Separate routes between buildings and data centres? |
| Operators | How many SIP trunks (the operator’s phone lines and numbers over the internet), from which operators and over which physical routes? Can the operator reroute your numbers during an outage? |
| SBC | Redundant SBCs at different sites? Who manages them? |
| PBX servers | Clusters or redundant nodes in different data centres? What carries over at failover: queues, recording, reporting and integrations? |
| Licences | Does the system work if the licence server cannot be reached, and for how long? Check for each platform and version. |
| Cloud services | Teams, sign-in and suppliers’ cloud services: what works locally without them? |
| DNS and time | SIP often needs working DNS, including from the backup site. Time synchronisation is needed for certificates and logs. |
| Certificates | When do they expire, and who renews them? An expired certificate causes the same outage as a fault. |
| Integrations | Directory, CRM, patient record integrations, alarm systems and recording. |
| People and suppliers | On-call staff, access rights, contact lists and the supplier’s escalation path. |
Typical backup routes for redundant telephony
- Two SIP trunks from different operators, ideally over different physical routes and different access types, such as fixed and mobile.
- Redundant SBCs and PBX nodes at different sites.
- Local survivability in branch offices and hospitals, so they can still make calls when the link to the central site is lost.
- Call forwarding by the operator to a backup number or to mobiles when the PBX does not answer.
- Phone subscriptions that work independently of the PBX, or another PBX as a backup.
- A change in how you communicate: calls and chat over the internet instead of telephony, or Wi-Fi calling instead of the mobile network.
- Manual backup procedures when nothing works, such as Rakel (the Swedish radio network for emergency and public safety services), messengers and home visits.
Mobile networks are a good backup but no guarantee. During major power cuts they come under heavy load, and capacity in wireless networks normally cannot be guaranteed.
How to test continuity
- Tabletop exercise: walk through a scenario, such as a power cut, an operator outage, a data centre outage or a cyberattack, with the business, IT and your supplier. Who does what, and who is informed?
- Planned failover test in a maintenance window: shut down a node, disconnect a SIP trunk, switch off an SBC or cut the link to a branch office. Measure the time to recovery and what stopped working.
- Test calls after every test: inbound to the PBX and queues, outbound, internal, callback, alarms to DECT and recording. The route for 112 is checked according to the plan agreed with the operator and SOS Alarm.
- Backup power: test running on battery and generator, not just that they start.
- After major changes: upgrades, new operators and server moves.
- Evaluate: shortcomings go into an action list and are followed up at the next test.
What to document
- Dependency map and network diagram: what depends on what.
- Numbering plan and routing, including in fallback mode.
- Continuity plan with backup procedures: when it is activated, who decides and what is done step by step.
- Contact list for operators, suppliers, on-call staff and your emergency response function, on paper as well.
- Contracts, such as your support contract for PBX and Teams: availability, response time, resolution time, maintenance windows and service reviews.
- Test reports and change log.
- Material for incident reporting within 24 and 72 hours, if you are covered by the Swedish Cybersecurity Act.
Also consider what contracted availability means. According to the Swedish Post and Telecom Authority (PTS), 99 per cent availability around the clock equals just over three and a half days of downtime a year.
What do the authorities say?
PTS guidance for organisations that use telecoms services and the business continuity guidance from the Swedish Civil Defence and Resilience Agency (MCF) say broadly the same thing: map your dependencies, set measurable requirements, have backup solutions and practise using them. No Swedish law says how often an organisation should test failover. For organisations covered by the Swedish Cybersecurity Act, continuity and crisis management are part of the requirements, but the Act does not prescribe any particular technology.
This guide describes general practice. How much redundancy you need is decided by your own risk analysis. Our offering for resilient telephony for mission-critical operations is described on a separate page.
Last updated 14 October 2026.
Common questions
More questions
Is geo-redundancy a legal requirement?
Not in Sweden. For organisations covered by the Swedish Cybersecurity Act, continuity is part of the requirements, but the Act does not prescribe any particular technology. How it is achieved is up to each organisation, based on its risk analysis.
Are two operators enough?
Only if they are genuinely separate: different networks, staff and subcontractors. Two brands owned by the same operator give you no real backup.
How long should backup power last?
In Sweden, there is no general requirement for organisations that use telecoms services. Start from how long your organisation can tolerate an outage, and remember the phones, switches and SBCs, not just the servers.
How often should we test failover?
No Swedish law says how often. PTS and MCF say that backup solutions should be tested and practised. Common practice is at least once a year and after major changes.
Does 112 work when the PBX switches to fallback mode?
That needs to be checked. In Teams survivable mode, for example, no location information is sent with emergency calls, and emergency numbers may need a route of their own. Plan the 112 check with the operator and SOS Alarm.
Further reading
Solution
Critical communications
Resilient telephony, contact centre and alarms, with redundancy and backup routes, for organisations that cannot afford downtime.
Industry
Healthcare
Phone lines that patients can get through on, built for 24/7 operation, with changes that are planned and tested.
Solution
Support contracts and managed services
Support contracts with agreed response times, so that your communications work every day.
Product
Mitel OpenScape Voice
The SIP platform for large and distributed environments, with redundancy.
Let’s talk about your communications
Tell us where you stand today with your PBX, Teams or contact centre, and we will come back to you with a proposal. It costs nothing to ask.
